A2ZAPK

InstElectric - Electricity3.72

InstElectric - Electricity v3.72

Downloads: 757


Free

InstElectric - Electricity / Specifications

InstElectric - Electricity / Screenshots

InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72
Loading... InstElectric - Electricity 3.72

InstElectric - Electricity / Description

Tool to support the calculation of electrical installations that will allow the user (designer / electrician / technician) to perform electrical calculations easily and quickly.

· Dimensioning complete of low voltage circuits with the most frequent installation methods
· Phase cable size neutral protective conductor
· Criteria based on the admissible current of the cable voltage drop and overcurrent protection
· Designation of the most used cables.
· Circuits with automatic circuit breaker until In = 4000 A (Ir rating setting) maximum fuse In = 1600 A (gG type) maximum 12 conductors parallel per phase maximum size 630 mm²
· Estimate of the maximum short-circuit current (simplified method)
· Forecast of loads of a building destined to houses with several sections: dwellings common services commercial premises/offices and garage with/without infrastructure for recharging electric vehicles
· Reactive power of the capacitor bank for the compensation of the power factor (cos φ) and capacity (µF) of the capacitors
· C/K Factor for automatic capacitor bank
· Choice of installation system in the function of the circuit cable and its situation
· Power in an unbalanced three-phase system
· Overvoltages due to loss of neutral conductor earth fault and short circuit
· Electricity parameters of a single-phase or three-phase (balanced)
· Transformer performance
· Secondary voltage of a transformer acoording to switch position
· Size of trays and conduits
· Conduits characteristics according to the installation method
· Conversions of wire sizes (mm²-awg) and conduits threads
· Representation of the curves of the protections
· International protection IP - IK

Parameter settings for calculations:
· Constants (voltages conductivity temperatures etc.) that affect electrical calculations
· Protections (circuit breakers and fuses)
· Selection of minimum rate for circuit-breakers with regulation and maximum cable size for multi-conductor grouping per phase
· Method estimation of the reactance
· Conductivity of the conductor depending on the current of the circuit (constant according to the expected current maximum cable temperature)
· Use reduction factors by grouping cables/circuits
· Use of factors of diversity/utilization

· Reference documents: IEC Standards REBT (sp) Technical Application Guide (UE) 2016/364

IN NO CASE SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT OR INDIRECT DAMAGES AS A RESULT OF THE CORRECT OR INCORRECT USE OF THE APPLICATION

Show More >

InstElectric - Electricity / What's New in v3.72

* Minor fixes

Choose Download Locations for InstElectric - Electricity v3.72



Telegram

.

InstElectric - Electricity / Tags

Share InstElectric - Electricity At Social Media

.